CLICK HERE FOR OUR COLOURS

GENERAL DESCRIPTION

SUPER ROOF™ is the Heavy Industrial Acrylic water-based coating that dries to a low sheen finish. SUPER ROOF™ has proven itself over the past 40 years as the Hard-Wearing Paint, having covered several million square metres in cold, wet and hot areas with pride and most of it is still lasting.

  • Outstanding Exterior Durability;

  • Water Resistant;

  • Superior UV Resistant;

  • Stain and Scrub Resistant;

  • Excellent Alkali Resistance;

  • Fast Drying and Over Coating Properties;

  • Can be applied to Damp Surfaces;

  • Water based, therefore all equipment can be cleaned with water;

  • Very low odour.


Non-toxic and non-irritant if standard painting conditions and code of painting practice is adhered to.


USES

SUPER ROOF™ is a finishing paint for interior and exterior surfaces. Recommended finishing paint for:


  • Galvanised Iron Roof Sheets;

  • Fibre Cement Roofs;

  • Sealing of Asbestos Roofs;

  • Cement Roof Tiles;

  • Fibre Cement Facias and Barge Boards;

  • Aluminium Gutters;

  • PVC Gutters;

  • PVC Pipes;

  • Concrete Floors;

  • Concrete Paving;

  • Concrete Structures;

  • Steel Draw Bars and Bull Bars;

  • Agricultural Equipment;

  • Truck & Trailer Chassis;

  • Steel Storage Containers;

  • Garden Pots, Statues and Décor;

  • Timber Benches;

  • Furniture;

  • Etc, Etc, Etc.


An appropriate primer should be used. Outstanding finishes obtained on new and previously painted surfaces in sound condition. Highly recommended for all above surfaces where a low sheen, good adhesion, alkali resistance and water resistance are required. Can be used in conjunction with Classic Roof Proof™ Waterproofing Agent


TECHNICAL DATA

All above technical data are based on SUPER ROOF™. Coverage / spreading rate of colours depend on condition and porosity of the surface and the manner in which SUPER ROOF™ is applied and used.


  • TYPE  -  Acrylic Copolymer Emulsion;

  • DRYING TIME  -  Surface: 1/2 - 1hour (23° Celsius and 50% Relative Humidity);

  • HARD DRY  -  3 to 4 hours (at 23° Celsius and 50% Relative Humidity);

  • OVERCOATING  -  4 to 8 hours depending on weather conditions;

  • VISCOSITY  -  100 - 104 KU;

  • SPECIFIC GRAVITY  -  1.23 - 1.27;

  • FINISH  -  Low Sheen;

  • WEIGHT SOLIDS  -  44 - 49%;

  • VOLUME SOLIDS  -  34 - 46% (100u wet film will give 35u dry film);

  • SPREADING RATE  -  8 - 10 m²/litre (to obtain a continuous film without full coverage;

  • COVERAGE (THEORETICAL)  -  7 - 8m²/liter;

  • FLASH POINT  -  Not applicable;

  • COLOUR RANGE  -  20 Standard Colours;

  • PACKING SIZE  -  1 Liter, 5 Liters and 20 Liters.


Coverage / spreading rate of colours depend on condition and porosity of the surface.


APPLICATION

  • READY  -  for use with brush or roller;

  • SPRAY  -   Apply only with large nozzle – minimum 2,4mm or air-less system;

  • THINNING  -  When used as sealer/primer use Maximum 10% water;

  • EQUIPMENT CLEANING  -  Water.


STANDARD APPLICATION PROCEDURE

NEW SURFACES

Clean thoroughly by removing all foreign matter with a wire brush, hosing Fibre Cement down with water and using a clean garden broom to remove all loose Cement Roof Tiles dust and dirt. Any Oils or Releasing Agents must be removed with Muriatic Acid or an Industrial Grade Degreaser, then washed with sugar soap. Hose all soaps and chemicals thoroughly down with water. Leave to dry before applying paint.

  • Apply one coat of Classiseal Pigmented Emulsion Primer;

  • Allow to dry;

  • Apply two coats of SUPER ROOF™ Paint allowing at least 4 hours drying time between coats;

  • Allow at least 4 hours drying time between coats;

  • Classiseal Primer can be replaced by using SUPER ROOF™ Paint diluted with 10% water as a Primer;

  • Allow to dry and overcoat with one coat of SUPER ROOF™ Paint undiluted.


PREVIOUSLY PAINTED SURFACES

It is recommended that existing roofs are washed with a high-pressure machine and an Anti-Fungicidal Wash. Any sign of fungal growth on fibre cement roofs must be removed by treating with Anti-Fungicidal Wash or household bleach before painting:

  • Wash down with water or detergent to remove all dirt, grease and paint other contaminants;

  • Galvanised roofs that show any sign of rust must be cleaned and spot primed with an appropriate primer;

  • Allow to dry;

  • Apply one coat of SUPER ROOF™ paint if surface is in sound condition;

  • Apply second coat of SUPER ROOF™ paint for change of colour, allowing at least 4 hours drying time between coats.


Roofs previously painted with gloss paint or alkyd type roof paint can be painted after cleaning and pre-treatment as above.


GALVANISED IRON

Use wire brush to remove all flaking paint and brush all surfaces to rough. Remove all grease, oil and fabricators sealing treatment with any recognised brands of galvanised iron pre-cleaner as directed. After cleaning wash down with water and allow drying. Apply two coats of SUPER ROOF™ paint allowing at least 4 hours drying time between coats.


  • Clean surface as directed above;

  • Apply one coat of Red Etch Primer or Calcium Plumbate Primer, depending on the severity of coastal condition;

  • Allow to dry;

  • Apply two coats of SUPER ROOF™ paint allowing at least 4 hours drying time between coats.


PRECAUTIONS

  • Do not apply direct to new galvanised iron, sand blasted steel or aluminium;

  • Application to areas where temperature exceeds 60° Celsius is not recommended;

  • Application to cold surfaces below 5° Celsius is not recommended;

  • Pre-wet new asbestos surfaces before painting;

  • For diluting use water only if required;

  • Do not use Mineral Turpentine, Lacquer Thinners or Meths for diluting as this will alter or destroy the quality and performance of SUPER ROOF™;

  • Clean all equipment and tools with water after use;

  • Do not apply to roofs which are used for the collection of drinking water use;

  • Clean all equipment and tools with water after use.


IMPORTANT

  • The ambient temperature must be between 5ºC and 33ºC and humidity between 10% and 80%;

  • Do not paint too early as the wall may still be damp - paint only when the walls are dry;

  • Do not paint in too hot weather, rather paint early morning and after lunch, the slower the paint dries, the longer it lasts;

  • Excessive application thickness and/or rapid drying could lead to cracking;

  • Avoid applying under adverse weather conditions as this could result in poor product performance;

  • Excessively friable surfaces should be cleaned down prior to primer application;

  • To assure smooth surface, paint corner to corner - from top to bottom - never halfway up and half way down;

  • Apply wet on wet, roll top to bottom overlapping half wet half dry.


SAFETY

Painting is a relatively user-friendly activity if the proper precautions are taken to ensure safety

  • It is advisable to wear gloves as Roofproof is difficult to remove from skin;

  • Always keep out of reach of children and animals;

  • Do not take in orally - harmful if swallowed. Seek medical attention and do not induce vomiting;

  • If accidental contact with skin, wash immediately with soap and water or a good quality skin cleaner;

  • If accidental contact with eyes, rinse immediately with plenty of water and seek medical advice;

  • Wear a respirator if the area being painted cannot be adequately ventilated, and work for short periods only;

  • Ventilate the area to be painted, opening all doors and windows and using fans during application and drying;

  • Protect floors with cloth Drop Cloths, not plastic, which is far more slippery;

  • Do not paint or store paint near any heat source such as a water heater or fireplace, and never smoke while painting;

  • Make sure your ladder is in good shape. Set the legs on an even surface and lock the cross braces. Do not stand on the top of the ladder nor on the utility shelf. If you are having difficulty reaching a spot, get down from the ladder and move it rather than leaning out;

  • Clean up carefully and thoroughly when you are done for the day;

  • If rags have alkyd paint or thinner on them, leave them to dry outside to avoid any chance of spontaneous combustion;

  • Choose an area inaccessible to children and pets, and when they are thoroughly dry, take them to a toxic-waste dump site.


GENERAL

Different surfaces and environmental conditions require specific painting systems to produce the best possible results - It is, therefore, recommended that you contact a representative from Classic Paints for advice on all your painting requirements, whenever possible.

The information, and, in particular, the recommendations relating to the application and end-use of Classic Paints products, are given in good faith based on Classic Paints’ current knowledge and experience of the products when properly stored, handled and applied under normal conditions. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the Product Data Sheet for the product concerned, copies of which will be supplied on request.


ISSUE

20/05/2022 - This supercedes all previous publications - This technical data furnished is obtained from controlled laboratory tests under ideal application conditions. No guarantee of any performance characteristic is given or implied and we do not hold ourselves responsible for any consequential damage of whatsoever nature that may arise from use of our products. In the event of a proven product fault our liability will be limited to the replacement of the product only. It is the users responsibility to confirm the currency of product data sheets.


Download as Pdf Document